Standard specifications
Carcass
:
Steel cord, nylon fabric, polyester fabric
Tensile strength
:
100〜6,000N/mm
Belt width
:
300〜3,200mm
Flame resistant standards
:
ISO, DIN, AS, MSHA, CSA, JIS
Belt length
:
Steel cord belts 50m and over, fabric belts 10m and over
Flame resistance test
General purpose cover rubber
Catching fire
Immediately after removal of burner
Three minutes after removal of burner
After removal of buraner, test sample is still keeping fire and completely burning out.
Flame-resistant cover rubber
Catching fire
One minute after removal of burner
In an air current No flame appers
One minute after removal of burner, fire is extinguished.